Phonic-Trap® sheath 6M - Ø152MM | Sound Reduction for Ventilation
Phonic-Trap® sheath 6M - Ø152MM | Sound Reduction for Ventilation
- Increased longevity with sustainable materials
- Compatible with various ventilation systems
- Tool-free installation using included clamps
- Vibration protection
- Ideal for industrial and domestic environments
Product presentation
The Phonic-Trap® 6M Duct - Ø152MM is designed to effectively reduce the noise of ventilation, heating and air conditioning systems. This superior quality soundproof duct is made in France and is distinguished by its comfort of use thanks to its non-allergenic materials and its easy installation. With the Phonic-Trap Duct, benefit from a significant reduction in noise pollution while ensuring optimal air circulation.
Noise Reduction: Unparalleled Performance
The Phonic-Trap Duct reduces the noise of ventilation devices by 50% compared to conventional ducts. Thanks to its innovative acoustic capabilities, this duct offers immediate noise attenuation, making your environment more peaceful and comfortable.
"Since I installed the Phonic-Trap Duct, the noise from my fans has been reduced by half. A real gain in comfort for my crops." - Opinion from an expert grower
Composition and Technical Characteristics
The Phonic-Trap® Sheath is made up of three distinct layers, each offering specific advantages:
- Outer Layer: Black aluminum foil reinforced with tear-resistant non-woven fiber. This vapor barrier layer combines flexibility and rigidity, making installation easier without compromising airflow.
- Internal layer: Acoustic insulation in non-allergenic polyester wadding, 25 mm thick. This material ensures a long lifespan because its fibers do not break and offers optimal comfort during installation: does not itch, does not scratch, non-allergenic.
- Technical layer: Microporous fabric with special anti-noise pattern, reinforced by a spiral steel wire reinforcement. Designed to maximize sound attenuation, this layer is state-of-the-art.
Benefits and Use
The Phonic-Trap® Sheath is ideal for growers and individuals wishing to improve the acoustic comfort of their growing or living spaces. Its main advantages include:
- Noise Reduction: Reduces noise pollution by 50%.
- Quality Materials: Made of non-allergenic materials that are comfortable to handle.
- Ease of Installation: Delivered with two clamps for quick and secure installation.
- Versatility: Suitable for all types of rooms, whether very humid or very dry.
- French manufacturing: 100% French design and manufacturing, a guarantee of quality and durability.
Technical characteristics
- Brand: Phonic-Trap®
- Description: PHONIC TRAP® SHEATH 6M - Ø152MM PRE-CUT
- EAN code 13: 3701084300235
- Frame: Spiral steel (lead, mercury or cadmium free)
- Outer Layer: Non-woven black aluminum foil, vapor barrier and anti-tearing
- Insulation: Polyester wadding, non-irritating, thickness 25 mm
- Internal Wall: Flexible microporous non-woven copolymer
- Max pressure: 2100 Pa
- Temperature: from -20°C to 80°C
- Internal Diameter: 152 mm
- Length: 6 meters
- Certification: REACH standard
- Manufactured: France
- Includes: 2 hose clamps
- Cartoning: Special and reduced size cardboard packaging
- Installation: Any room: from very humid to very dry
- Use: Soundproof sheath for ventilation, heating, air conditioning devices
Questions answers
Q: Is the Phonic-Trap easy to install?
A: Yes, it is very easy to install thanks to its optimal flexibility and rigidity, as well as the two clamps included.
Q: Can the Phonic-Trap be used in high humidity environments?
A: Yes, the sheath is designed to be used in all types of rooms, whether very humid or very dry.
Q: What materials make up the Phonic-Trap Sheath?
A: The sheath is made of non-woven black aluminum foil, non-allergenic polyester wadding insulation, and a microporous fabric with steel reinforcement.
Q: How long is the Phonic-Trap Sheath?
A: The Phonic-Trap Sheath is 6 meters long.
Q: Is the Phonic-Trap Sheath compatible with all types of ventilation devices?
A: Yes, it is compatible with air extractors, air intractors, aerators, VMC, air conditioners and heating systems.
With the Phonic-Trap® 6M Sheath - Ø152MM , benefit from a high-performance and comfortable acoustic solution, designed to meet the strictest requirements of growers and individuals concerned about their sound environment.
Features detailed
| Certification | REACH |
|---|---|
| Type | Duct |
| Material | Intissé microporeux perforé, ouate polyester 25mm, aluminium plastifié avec pare-vapeur |
| Compatibility | Ventilateurs standards Ø152mm, extracteurs HVAC, gaines aluminium ou PVC, silencieux PhonicTrap courts |
| Frame | Acier spiralé sans métaux lourds |
| Diameter (mm) | 152 |
| Length (m) | 6 |
| Sound insulation | Oui |
| Temperature range (°C) | -20°C à +80°C |
| Manufacturing origin | France |
| Maximum pressure | 2100 Pa |
| Noise reduction | ~50% vs gaines classiques |
Reviews customers
Soyez le premier à donner votre avis !
Partagez votre expérience avec ce produit.
Your questions
Does a 50% noise reduction indicate that the pressure loss in the duct remains reasonable for a LED SCROG/LST ventilation system requiring optimal airflow?
Is it great to reduce noise but does the Phonics Trap sheath withstand the heat produced by the LED fans in an indoor box without deforming?
Does the Phonic Trap duct really reduce the noise of my air extractor by 50 without affecting the airflow?
Is the 50% sound reduction measured on continuous or intermittent sound and on which specific frequency range to optimize the choice in growth g/Watt?
The announced 50% sound reduction for the Phonic-Trap® Hülle 6M - Ø152MM is measured on continuous sound, typical of the noise generated by fans and air flow in ventilation. This treatment effectively acts on the constant air flow, with no measurement indicated for intermittent sound.
The precise frequency range is not explicit, but the reduction mainly concerns the low and mid frequencies characteristic of moving air noise and electric motors.
For indoor cultivation, where ventilation generally operates continuously, this sound reduction improves comfort while maintaining optimal energy consumption, contributing to an excellent ratio grams per Watt.
Does the Phonic Trap 6M Ø152MM reduce ventilation noise by 50 percent, but does it impact air flow in compact micro-culture?
What is the pressure loss or impact on air flow when installing the Phonic-Trap® 6M Ø152MM duct?
The Phonic-Trap® 6M Ø152MM duct is specifically designed to provide significant sound reduction while maintaining excellent air flow. Thanks to its three-layer structure, including a perforated inner lining and polyester wadding insulation, it minimizes pressure loss and thus limits the impact on air flow.
Its reinforced metal spiral prevents kinks and blockages, ensuring smooth circulation. Although a very slight reduction in flow may occur in some cases, it is generally negligible in a proper installation with an appropriate quick connection kit that ensures sealing.
In summary, this duct effectively combines silence and performance, offering an excellent compromise with minimal pressure loss.
Is compatible with 80x80 extraction, is there a risk of loss of flow with this Phonic-Trap duct 152mm 6m?
The Phonic-Trap® 6M - Ø152MM duct is ideal for reducing noise in a ventilation system, but its diameter of 152 mm does not match an 80x80 mm extraction. This implies a potential need for an adapter.
Regarding the flow rate, a wider duct like this offers a larger air section, which can limit the loss of flow. However, the microporous structure and polyester wool designed for sound attenuation can create slight resistance to the passage of air, leading to a moderate decrease in flow rate.
To ensure optimal operation, it is important to avoid excessive bends and to properly size the system, especially when connecting different diameters. This way, you can fully benefit from its acoustic qualities without compromising ventilation.
Does the Phonic-Trap duct provide adequate resistance for a pressure close to 2000 Pa in an 80x80 extraction circuit?
The Phonic-Trap® 6M - Ø152MM duct is designed to be robust and effectively reduce noise disturbances while remaining flexible thanks to its helical steel core. It handles common pressures in powerful extraction systems well.
However, a pressure close to 2000 Pa is high for a flexible duct, especially in a circuit with a cross-section of 80x80 mm where the risk of deformation exists. Without precise technical specifications regarding this pressure, it is advisable to prefer a rigid or reinforced duct to ensure the stability of the circuit.
In summary: the Phonic-Trap® is very suited for average pressures and excellent acoustic treatment, but for 2000 Pa in an 80x80 circuit, it may not provide optimal resistance.
Does the Phonic-Trap 152mm duct generate a significant pressure loss affecting air flow and ventilation efficiency?
The Phonic-Trap 152mm duct is specially designed to reduce noise from ventilation systems without causing significant pressure loss. Thanks to its internal three-layer structure, it ensures smooth air passage while limiting the impact on air flow. Thus, it guarantees optimal efficiency of your ventilation without compromising performance, provided it is properly installed with an appropriate diameter.
What is the pressure loss added by the Phonic-Trap® 6M Ø152 mm duct compared to a standard PVC duct for ventilation efficiency?
Can this acoustic duct easily connect without leaks to all standard fan brands with a diameter of 152mm?
The Phonic-Trap® Hülle 6M - Ø152MM acoustic duct is designed to reduce noise while ensuring good airflow. For an easy and leak-free connection with all standard 152 mm fans, it is advisable to use a quick connection kit that guarantees optimal sealing. Depending on the installation, some adapters may be necessary to achieve a perfect fit.
What is pressure loss with the Phonic Trap 6M diameter 152mm compared to classic ducts to evaluate the impact on ventilation efficiency?
The Funda Phonic-Trap® 6M diameter 152mm is designed to provide a minimal pressure loss compared to classic ducts, significantly limiting its impact on ventilation efficiency.
Its innovative triple layer—a perforated inner lining, a woven polyester insulation layer, and an outer aluminum cover with a metal spiral—allows air to flow freely while reducing back pressure and flow resistance. Thus, the duct effectively attenuates noise without increasing pressure in the system, ensuring efficient and quiet ventilation.
In summary, this unique design combines sound insulation and smooth airflow to preserve the power of your fan while limiting noise disturbances.
Does the 50 percent noise reduction with the Phonic-Trap duct significantly decrease air pressure and affect the flow rate in a LED-lit ventilation system?
The Phonic-Trap® sheath 6M - Ø152MM allows for a noise reduction of up to 50% compared to standard ducts, while ensuring optimal air circulation. Its three-layer design is intended to limit noise without causing significant air pressure loss or impacting the flow rate in your LED-lit ventilation system.
Feedback from experienced users confirms that this duct improves acoustic comfort without compromising the necessary extraction performance for effective cultivation.
In summary, you benefit from a significant noise reduction without notable loss in air pressure or flow rate, making it an excellent choice for a comfortable and efficient indoor growing environment.
Does the announced 50% noise reduction significantly impact static pressure and thus air flow in a ventilation system with this Phonic Trap 6m Ø152mm duct?
The Phonic-Trap® sheath 6M - Ø152MM is specially designed to reduce noise by up to 50% while significantly limiting its impact on static pressure and air flow. Thanks to its optimized triple-layer structure, it offers a negligible pressure loss, ensuring smooth air passage.
In practical terms, this means that the flow resistance remains low, and the static pressure of your ventilation system is not significantly affected. Therefore, you benefit from a substantial noise reduction without compromising the optimal performance of your air extraction or renewal.
What is the impact of the maximum pressure of 2100 Pa on the choice of this acoustic duct in a specific ventilation system?
Is the claimed noise reduction over the total length of 6 meters uniform, or is there a noticeable degradation in acoustic performance as one approaches the ends of the sheath?
What is the approximate pressure loss over 6 meters of the Phonic-Trap 152mm duct and how does it impact the performance of my ventilation system?
The pressure loss over 6 meters of the Phonic-Trap® 6M - Ø152MM is virtually negligible thanks to its optimized triple-layer design. This structure significantly limits air resistance, allowing the ventilation system to maintain a nearly intact flow without overloading the fan.
Specifically, the duct supports a high maximum pressure (2100 Pa), which prevents any sagging and ensures excellent efficiency even over long distances. You benefit from a high-performance and quiet operation, with noise reduction of up to 50% without compromising ventilation.
What is the average pressure loss on the Phonic-Trap 6M Ø152MM in continuous use and how does this impact the overall performance of the ventilation system?
The average pressure loss on the Phonic-Trap 6M Ø152MM in continuous operation remains minimal, even negligible compared to a standard PVC duct. Its triple-layer design, with a perforated inner layer, ensures smooth air circulation without straining the fan.
This low pressure loss allows for excellent air flow and prevents any overpressure that could harm performance or require additional power. Thus, the duct provides a significant reduction in noise while maintaining the overall and energy efficiency of the ventilation system.
Viewed recently