Meliflor 3-in-1 EC, TDS and Temperature Meter

Monitor irrigation water with the Meliflor 3-in-1 meter: electrical conductivity (EC), total dissolved solids (TDS) and temperature. Its pen design, HOLD function and automatic shut-off make routine checks easier in hydroponics and when mixing nutrient solutions.

More details

29,90 €TTC
tax incl.

Unavailable

GrowLED…Calculating the dispatch time…

Secure payment CBPayPalAlma
Professionals: volume discounts and quotes

Quote · Lighting study · Administrative Payment Order

Not comfortable with this step yet?

Step 8 · Arrosage & irrigation · 10 min, gratuit

GrowLED since 2009
French group · indoor growing expertise
Pay in instalments
3 or 4 payments from €50 with Alma, subject to eligibility
24h express available
After dispatch, if offered at checkout
Showroom near Nancy (54)
Au Palétuvier · Champigneulles
Meliflor 3-in-1 EC, TDS and Temperature Meter
Meliflor 3-in-1 EC, TDS and...
29,90 €
Parraine tes proches
5 % pour toi & 5 % pour ton ami
Créer mon compte
Description

Product presentation

Meliflor 3-in-1 EC, TDS and Temperature Meter

Take a reading of your water and nutrient solution before watering. The portable Meliflor meter combines EC, TDS and temperature so you can compare your source water with the mixed solution and track changes between watering sessions.

Brand : Meliflor
Measurements : EC · TDS · Temperature
EC : 0–9,999 µS/cm
TDS : 0–9,999 ppm
Temperature : 0.1–80 °C
Automatic shut-off : After 10 minutes of inactivity

Useful readings when preparing irrigation water

  • Compare before and after adding nutrients — EC provides an indication of the overall concentration of dissolved salts. Measuring the source water and then the mixed solution helps you track preparation.
  • Keep a record of your settings — The HOLD function freezes the reading on screen while you record it in your growing log.
  • Check several containers — The pen design is easy to carry between a mixing container, a reservoir and a water sample.
  • Reduce unnecessary battery use — Automatic shut-off after 10 minutes of inactivity helps conserve battery power.

Understanding the readings

EC in µS/cm expresses the electrical conductivity of the solution. TDS in ppm estimates dissolved solids from that measurement. Temperature completes the reading. This device measures these three parameters; use a separate pH meter to check acidity. An EC/TDS reading does not identify individual nutrients and cannot establish whether water is safe to drink.

Technical specifications

TypePortable digital pen meter
EC range0–9,999 µS/cm
TDS range0–9,999 ppm
Temperature range0.1–80 °C
Stated accuracy±2% — conditions and applicable parameter are not specified
HOLD functionFreezes the displayed reading
Automatic shut-off10 minutes of inactivity
Probe protectionRemovable cap

Getting started and taking a reading

  1. Place a sample of the solution in a clean container and mix it before checking.
  2. Remove the cap, switch the meter on and select the required measurement mode.
  3. Immerse only the probe section, up to the marked immersion limit. Keep the body and controls dry.
  4. Wait for the reading to stabilise. Press HOLD if you want to freeze it and note the displayed unit.
  5. After checking, rinse the probe, switch the meter off and replace the cap once the probe is clean and dry.

Caring for the meter

Rinse the probe with clean water after each use, especially after testing a nutrient solution. Avoid deposits, impacts and abrasive rubbing of the contacts. Store the capped meter in a dry place. Follow the instructions for this model for checks or calibration; do not apply a procedure intended for a pH probe.

GrowLED tip : Record the EC of your water before adding nutrients, then measure the prepared solution. Always compare readings in the same unit: 1,000 µS/cm equals 1 mS/cm. Before comparing ppm readings from two meters, check their TDS conversion factors.

Frequently asked questions

Does this meter also measure pH?

No. It measures EC, TDS and temperature. A separate meter is needed for pH.

Can I use it in a nutrient solution?

Yes, hydroponics is among its stated uses. Mix the solution before measuring and rinse the probe after each use.

Can the whole meter be submerged?

No. Respect the probe immersion limit and keep the body dry. No waterproof rating for the body has been confirmed.

Do ppm readings show how much of each nutrient is present?

No. TDS is an overall estimate of dissolved solids. It does not identify individual elements or their concentrations.

They've adopted it

Reviews customers

Soyez le premier à donner votre avis !
Partagez votre expérience avec ce produit.

Frequently asked questions

Your questions