Présentation du produit
Cli-mate Temperature Controller 16 A
Up to 16 A continuous • Digital touch display • Settings memory • 5 m sensor
This controller switches a heater, fans or an air conditioner on and off according to measured temperature. It accepts up to 16 A in prolonged operation, making it capable of driving appliances far hungrier than a simple extractor.
What sets it apart: the 16 A. Most controllers in the range drive fans; this one also takes a heater or an air conditioner, with no extra relay.
Driving heating, not just ventilation
Regulating a grow room is not only about removing heat. In winter, or during the dark period, temperature can drop too low and slow growth. This controller drives either a device that warms or one that cools, depending on the mode selected.
A 5-metre sensor that changes the install
The 5-metre cable lets you place the unit where it is accessible — outside the space, near the socket — while measuring temperature exactly where it matters. That is what separates accurate regulation from approximate regulation.
Memory, the detail that avoids nasty surprises
After a power cut, the unit recovers its configured values instead of reverting to factory settings. On an installation running unattended, that is what stops you finding an out-of-spec grow room on your return.
A housing built for the load
Passing 16 A through a compact unit calls for construction to match. The manufacturer states a fire-resistant plastic alloy rated for high temperatures — which matters on a device meant to switch heavy loads for long periods.
Technical specifications
- Device type : on/off temperature controller
- Compatible appliances : heaters, fans, air conditioners
- Admissible current : up to 16 A in prolonged operation
- Operating modes : two
- Interface : digital screen with touch buttons
- Memory : values recovered after a power cut
- Sensor : high-precision temperature probe, 5 m cable
- Housing : fire-resistant, high-temperature plastic alloy
- Weight : 0.5 kg
- In the box : 1 controller, 1 sensor with 5 m cable
In the same range
- Cli-mate Humidity Controller Humi – humidistat, 16 A
- Cli-mate Climate Station Total – lighting and full climate, 7 A
- Cli-mate Dual-Flow Controller Twin Humi – humidity, 8 or 24 A
GrowLED tip :
If you are driving a heater, leave a large enough gap between the heating setpoint and the ventilation setpoint: otherwise the two appliances take turns continuously and burn power for nothing. Two to three degrees is usually enough.
Joseph – Directeur de GrowLED








