Je recommande vivement cette sonde, elle garantit une précision optimale et une utilisation simple. Emballage soigné, installation facile. Je compte en prendre d'autres pour mes amis.

Replacement pH probe - BlueLab
Replacement pH probe - BlueLab
Discover the Bluelab replacement probe for pH meter which fits the Bluelab Combo, Guardian and pH Meter models.
Features detailed
| Marque | Bluelab |
|---|---|
| Type | Sonde pH |
| Compatibilité | Bluelab (Guardian, pH Meter, pH Pen) avec connecteur BNC |
| Dosage recommandé | Rinçage à l'eau propre fraîche, 3 à 5 gouttes de solution KCl par semaine, nettoyage avec Bluelab pH Probe Cleaner ou détergent doux |
| Densité du mylar | Polypropylène |
| Accessoires inclus | Capuchon de stockage avec solution KCl, ventouse |
| Longueur du câble (m) | 2 |
| Précision | Nécessite étalonnage régulier pour maintenir la précision |
| Étalonnage | Régulier avec tampons pH 4, 7 et 10 |
| Connecteur | BNC |
Reviews customers
Très bon produit. J'ai
Très bon produit. J'ai testé plusieurs solutions avant, et celle-ci est vraiment la meilleure. Fonctionne parfaitement, consomme peu. Livraison rapide et bien emballée. Service client très réactif. Je suis vraiment satisfait et je vais certainement en racheter.
Aucun avis ne correspond à ce filtre.
Your questions
Hello, is this BlueLab replacement pH probe compatible with all BlueLab models or only with specific ones?
Is the BlueLab pH replacement probe compatible with all BlueLab device models or are there specific restrictions depending on the models?
Is the replacement pH probe BlueLab Reference SONDE-RECH-PH-BLUELAB factory calibrated or does it require calibration before use to ensure an accurate reading?
Is the BlueLab Reference pH probe compatible with all BlueLab models or only with specific devices?
What is the ideal frequency for changing the Bluelab pH probe in hydroponics to ensure reliable long-term measurements?
What is the average durability of this BlueLab pH replacement probe in an indoor growing environment with daily use?
Is this BlueLab pH replacement probe compatible with all BlueLab models or only certain specific devices?
What precision and recalibration frequency for the Bluelab Reference pH probe to ensure optimal performance with minimal consumption?
The Bluelab Reference pH probe offers excellent accuracy to ensure reliable pH control, essential for optimal growth under LED lighting. To maintain this accuracy, it is recommended to recalibrate the probe every 1 to 3 months, depending on your usage frequency and growing conditions.
To limit consumption and extend the lifespan of your probe, ensure that the tip remains moist by using the storage cap filled with KCl between uses. Regular maintenance with suitable cleaning and calibration solutions will help ensure stable performance while avoiding excessive recalibration.
Such rigor in maintenance guarantees you optimal performance with minimal intervention for healthy and controlled cultivation.
Is the blue lab reference pH probe compatible with all versions or just specific models?
What are the recommended accuracy and recalibration frequency for the BlueLab Reference pH probe to ensure optimal performance with minimal consumption?
To ensure optimal performance while preserving the probe, it is recommended to recalibrate the probe after each cleaning. This regular cleaning with a suitable care kit and keeping the probe moist in its KCl solution prevents drift and excessive recalibration.
If the probe is used in a critical environment, recalibrating before each measurement session is advisable. Otherwise, a regular frequency, such as weekly, depending on usage, helps maintain accuracy while limiting wear.
Finally, to minimize consumption, it is better to keep the probe submerged in the measured solution and use the specific BlueLab calibration solutions.
What is the ideal frequency for replacing the BlueLab pH probe to ensure accurate measurements in a hydroponic system?
The ideal frequency for replacing the BlueLab pH probe in a hydroponic system primarily depends on its condition and the quality of measurements. There is no fixed duration.
To ensure optimal accuracy, it is essential to:
- clean and hydrate the probe before each use,
- perform monthly calibrations with standard solutions,
- keep the probe moist between uses with a storage cap and fresh KCl solution.
With proper maintenance, the probe can last several months. Consider replacing it as soon as measurements become unstable or erroneous despite rigorous maintenance.
What is the maximum precision for pH reading for this BlueLab probe in microculture?
What is the pH measurement accuracy under optimal conditions and the recommended calibration duration for this BlueLab Reference probe?
What is the average stabilization time of the BlueLab Reference pH replacement probe SONDE-RECH-PH-BLUELAB in a micro-culture environment?
The average stabilization time of the BlueLab Reference pH replacement probe SONDE-RECH-PH-BLUELAB in a micro-culture environment is not specifically stated by the manufacturer. In practice, for this type of professional double-junction probe, stable readings usually occur within a few seconds to a minute after immersion.
However, to achieve the best accuracy, it is important to regularly maintain the probe (cleaning and calibration) and ensure that the tip remains moist by using its storage cap with KCl solution. These good practices ensure a reliable and quick response during measurements.
What is the ideal frequency to recalibrate this BlueLab pH probe to ensure accurate measurements in intensive cultivation?
In parallel, daily pH checks using a portable handheld device are advised for optimal monitoring. Finally, do not forget that recalibration is mandatory after each cleaning of the probe to maintain its accuracy.
These simple yet crucial steps ensure rigorous and effective monitoring of your growing environment.
What is the pH accuracy and the optimal operating temperature of the BlueLab replacement pH probe 'sonde-rech-ph-bluelab' to ensure reliable readings in a hydroponic system?
The BlueLab replacement pH probe 'Ersatz-pH-Sonde' is designed to provide fast and reliable measurements in hydroponic systems. Its exact accuracy is not quantified, but it is well-suited for indoor cultivation, provided regular calibration with buffer solutions is performed to ensure accurate readings.
Regarding temperature, the probe operates optimally between 0 and 60 °C. This range perfectly matches the typical conditions in hydroponics, ensuring measurement reliability in this context.
For optimal results, ensure the probe is kept clean, regular calibration is performed, and it is used within the recommended temperature range.
What is the exact precision of this BlueLab pH replacement probe in hydroponic growing conditions under LED for intensive SCROG?
Does this BlueLab pH replacement probe offer full compatibility with the main BlueLab controllers to ensure accurate and reliable measurement in connected indoor cultivation?
However, some specific models, such as the BlueLab OnePen, require a dedicated probe, incompatible with this standard connector. Therefore, it is essential to check the exact model of your controller before purchasing to ensure full compatibility.
In summary: this probe is ideal for BlueLab controllers with BNC connector and will allow you to maintain a rigorous pH monitoring in your crops under horticultural LED lighting.
What replacement frequency do you recommend for this BlueLab pH probe in intensive use in small cultivation?
Monthly in-depth calibration is also important, especially in hydroponics or substrate. You should consider replacing the probe as soon as you notice a decrease in accuracy despite rigorous maintenance, to ensure optimal control of your cultivation.
What is the average lifespan of this BlueLab pH replacement probe under normal growing conditions?
Is this BlueLab pH replacement probe compatible with all BlueLab models or only certain specific ones?
The BlueLab pH replacement probe is compatible only with BlueLab models equipped with a BNC connection, such as the Combo Meter and the Guardian Monitor. However, it is not suitable for devices like the BlueLab OnePen that require a dedicated specific probe.
Before placing any order, it is therefore essential to check the exact model of your device. To ensure accurate measurements, also remember to regularly calibrate and maintain your probe.
What recalibration frequency do you recommend to ensure the optimal accuracy of the BlueLab pH probe in intensive growing conditions?
To ensure optimal accuracy of your BlueLab pH probe in intensive growing conditions, we recommend a calibration every 1 to 2 weeks. This frequency ensures the reliability of measurements in demanding conditions. Also, remember to clean the probe after each use and keep it hydrated in a KCl solution to extend its lifespan.
Finally, always use pH buffer solutions of 4.0 and 7.0 for your calibrations to achieve precise and consistent results.
Does this BlueLab Reference pH probe have confirmed durability for intensive use or is it mainly for occasional use?
What is the average lifespan of this BlueLab pH replacement probe under normal use?
Viewed recently