Produit arrivé rapidement, boîtier solide et prise en main immédiate. Les données s'affichent instantanément, ce qui simplifie grandement l'utilisation au quotidien. Un achat fiable pour ceux qui veulent la simplicité sans compromis.
Easily test the electroconductivity of your water, the temperature and its pH with the Combo EC/PH tester from BlueLab.
Equipped with two probes and without cable or power plug (operated with AAA LR03/LR3 batteries included).
There is also no need to calibrate the device which has already been carried out at the factory.
Accuracy: 0.1pH / 0.1 EC / 1°C
Features detailed
| Type | EC/PH/Température |
|---|---|
| Warranty (years) | 5 ans |
| Power supply | 2 AAA batteries |
| Calibration | pH 2-3 points manuel |
| Resolution | 0.1 pH/EC, 1°C |
| CO2 measurement range (ppm) | 0-14 |
Reviews customers
Pris par curiosité et franchement j'aime bien le côté tout en un pas besoin de changer l'appareil ça fait propre et rapide je trouve que ça fait le taf sans trop se prendre la tête le boîtier tient bien en main et ça s'utilise facilement pas eu besoin de me plonger dans le mode d'emploi super pratique pour un usage terrain bon achat
Après quelques jours d'utilisation
Après quelques jours d'utilisation intensive, je peux confirmer que ce produit tient ses promesses. Efficace, économique, et facile à mettre en place. Les résultats sont visibles rapidement. Le service client est top, très réactif. Livraison sans souci. C'est un bon rapport qualité-prix pour ce type de produit. Recommande.
Bon
Ça marche nickel.
Excellent rapport qualité-prix
Excellent rapport qualité-prix. Fonctionne comme prévu. Très content de mon achat.
Bon rapport qualité-prix
Bon rapport qualité-prix. Fonctionne parfaitement. Livraison rapide. Merci.
Très satisfait
Qualité au rendez-vous.
Top
Waouh, bravo !
Franchement, c'est du
Franchement, c'est du bon boulot. Reçu rapidement, bien protégé. Les résultats sont au rendez-vous.
Aucun avis ne correspond à ce filtre.
Your questions
Is the BlueLab EC/PH + Temperature combo tester compatible with a programming interface or an application for automating the measurement and recording of test results remotely?
What is the accuracy of this BlueLab - Combo EC/PH + Temperature tester compared to other common models? Can it be used continuously without risk of damage?
Is the EC and pH stable over time or does it need to be recalibrated often to ensure measurement reliability in cultivation?
The BlueLab – EC/PH + Temperature combination tester is recognized for its initial accuracy and stability, notably thanks to automatic temperature compensation. However, to ensure optimal reliability of pH and electrical conductivity (EC) measurements over the long term, it is essential to regularly recalibrate the device. This periodic calibration compensates for variations due to usage and changing conditions, ensuring the fidelity of the readings.
The frequency of calibration depends on usage and conditions, but regular maintenance with suitable calibration solutions and cleaning of the probes prolongs the accuracy and lifespan of your tester.
Is this BlueLab combo EC PH and temperature tester easy to calibrate and especially accurate for a first indoor installation?
The BlueLab – EC/PH + Temperature Combination Tester is known for its ease of calibration, especially for pH, thanks to an intuitive interface and a 'Cal' button that guides you step by step. No calibration is required for EC and temperature, which greatly simplifies its use for a first indoor installation.
Regarding accuracy, this tester is praised by professionals for its quality probes and automatic temperature compensation (ATC), ensuring reliable and consistent measurements.
In summary, this combination is perfectly suited for beginners, offering quick handling and reliable readings for optimal control of your crops.
What is the precision for the combined EC, pH, and temperature measurement on this BlueLab tester in compact microculture?
The BlueLab Combo EC/pH + Temperature tester offers precision suitable for microspace cultures: ±0.1 for EC and pH, and ±1°C for temperature. These values ensure reliable monitoring of essential parameters for healthy and optimized plant growth under LED.
What is the measurement accuracy for pH and EC with this BlueLab combo tester and how to best calibrate the device to ensure stable results in indoor cultivation?
The BlueLab Combo Meter offers a precision of ±0.1 for pH (in a range of 0 to 14) and for electrical conductivity EC (from 0.0 to 9.9), with a resolution of 0.1 for both parameters. The temperature is measured from 0 to 50°C with a resolution of 1°C.
To ensure stable results in indoor cultivation, calibration should be performed regularly:
- pH: calibrate at two points using standard buffer solutions (pH 7.0 and then pH 4.0 or 10.0) ideally before each use or at minimum once a week.
- EC: calibrate with an appropriate standard solution (for example, 1.41 or 2.76 mS/cm) to ensure accurate temperature compensation and proper calibration.
Do not forget to clean the electrodes regularly to avoid any buildup, and replace the double junction pH probe if you observe a loss of precision. The device incorporates automatic temperature compensation that optimizes the accuracy of the measurements.
Thus, by following this simple calibration routine, this tester will perfectly assist you in monitoring the essential parameters for the health of your indoor plants.
BlueLab Combo EC PH and temperature tester, accuracy in micro-culture 10x10 cm?
The BlueLab Combo EC/PH + Temperature Tester offers an accuracy of 0.1 pH, 0.1 EC, and 1°C, which perfectly suits monitoring essential parameters in your indoor crops. Even though it is not specifically designed for micro-cultures of 10x10 cm, it remains a reliable and easy-to-use tool for tracking the quality of your nutrient solutions in that type of environment. Its portability thanks to AAA batteries makes it a handy companion for continuously adjusting your settings.
Is it possible to integrate the BlueLab Combo EC/PH + Temperature tester into a remote monitoring system for real-time control of indoor growing parameters?
The BlueLab Combo EC/PH + Temperature tester is primarily designed for manual and local use, without native data transmission. For real-time remote control, a complementary system should therefore be considered: connected compatible sensors, suitable Bluetooth or Wi-Fi interfaces, or even a custom setup with a microcontroller to collect and transmit the data.
However, this requires skills in hardware and software development, as the device alone does not directly support remote monitoring. For more automated tracking, you might also consider solutions specifically designed for remote management of growing parameters.
Is the BlueLab - EC/PH + Temperature Combo Tester suitable for micro spaces?
The BlueLab - EC/PH + Temperature Combo Tester is perfectly suited for micro spaces due to its compact size (18 x 11 x 8.3 cm) and portability. It offers excellent accuracy: ±0.1 pH, ±0.1 EC, and ±1°C, ensuring reliable measurements to carefully monitor your nutrient solution.
Its 2-meter cable facilitates access in small volumes, while the backlit screen ensures good readability even in low-light areas. Easy to use and calibrate, this tester is ideal for passionate growers wanting to precisely control essential parameters of their crops in confined environments.
Can the BlueLab Combo EC/PH + Temperature tester be calibrated independently and is it accurate in hydroponic conditions over a long duration?
In hydroponic conditions, this tester remains reliable and accurate over the long term, provided regular maintenance of the pH sensor is performed (calibration, cleaning, hydration, and replacement when necessary). It also includes automatic temperature compensation that optimizes the accuracy of measurements in the face of thermal variations in the nutrient solution.
This design allows for sustainable and precise use tailored to the demands of indoor hydroponic cultivation.
Does this BlueLab combo tester measure temperature in real-time while measuring EC and pH, or do you need to take separate readings for each parameter?
Is it precise to measure EC, pH, and temperature at the same time, practical for beginners?
The BlueLab – EC/PH + Temperature Combination Tester is perfectly suited for beginners. It simultaneously measures pH, electrical conductivity (EC), and temperature, greatly simplifying the monitoring of nutrient solutions. Its automatic temperature compensation ensures accurate measurements, and its backlit display makes reading easy. Easy to use and reliable, it represents an excellent tool for quickly mastering these essential parameters for indoor cultivation.
Can this combo tester be easily calibrated to ensure accurate measurements in a differentiated growing environment?
The combo tester BlueLab – EC/PH + Temperature Combination Tester is very easy to calibrate to ensure accurate measurements in a differentiated growing environment. The pH calibration is done at two points, usually with buffer solutions at pH 7.0 and pH 4.0 (or pH 10.0), following a simple guided procedure. An error message indicates when recalibration is needed, securing your readings.
For conductivity (EC), the device is pre-calibrated at the factory and includes automatic temperature compensation, ensuring excellent accuracy without regular calibration. The temperature itself does not require specific adjustment.
For optimal accuracy in differentiated growing, it is recommended to use buffer solutions at the same temperature as your growing environment and to allow the probes to stabilize for a few minutes in the solution. This method guarantees the reliability of measurements while remaining simple and quick.
What is the accuracy of the EC measurement in mS/cm of the BlueLab Combo tester? Stability of the integrated temperature during measurement?
The temperature is measured in real-time via an integrated probe, ensuring dynamic monitoring and instant correction of the EC. This automatic compensation optimizes the stability and reproducibility of the measurements during data collection.
What is the recommended calibration frequency for this EC/PH combo tester to ensure accurate and reliable measurements?
Does this BlueLab tester allow for independent calibration of EC, pH, and temperature measurements for better precision during parallel growing sessions?
How does the BlueLab combo tester manage the accuracy of EC, pH, and temperature measurements simultaneously to ensure an optimal differentiated management between growth and blooming?
What are the accuracy levels and measurement range of the BlueLab Combo EC/PH + Temperature tester to ensure optimal control in hydroponics?
The BlueLab Combo EC/PH + Temperature tester offers excellent accuracy to ensure optimal control in hydroponics:
- pH: range 0.0 to 14.0, accuracy ±0.1, resolution 0.1 unit
- Electrical conductivity (EC): range 0.0 to 9.9 EC, accuracy ±0.1, resolution 0.1 EC
- TDS: up to 4950 ppm (500) or 6930 ppm (700), accuracy ±50 to ±70 ppm, resolution 10 ppm
- Temperature: 0 to 50 °C, accuracy ±1 °C, resolution 1 °C
It also includes automatic temperature compensation and simple two-point pH calibration, ensuring stable and reliable measurements throughout the process.
Does this BlueLab combo tester allow for easy field calibration to ensure accurate measurements on two crops in parallel with different EC and pH requirements?
For conductivity (EC), the sensor is factory pre-calibrated and does not require recalibration, making it easy to manage two crops with different needs simultaneously. Automatic temperature compensation ensures stable accuracy despite thermal variations.
With an accuracy of ±0.1 pH and ±0.1 EC, as well as integrated temperature measurement, this lightweight and portable device is perfectly suited for rigorous monitoring of nutritional parameters of crops in parallel, even under field conditions.
How to ensure accurate temperature reading while measuring EC and pH with this BlueLab Combo tester?
To ensure an accurate temperature reading while measuring pH and EC with the BlueLab Combo EC/pH + Temperature tester, it is crucial to first calibrate the pH at two points using buffer solutions. Electrical conductivity benefits from an integrated automatic temperature compensation, ensuring its accuracy without further calibration. The temperature is measured simultaneously by the same probe but does not require specific calibration.
For reliable measurements, it is essential to allow the probe to stabilize for a few minutes in the solution being tested so that the measured temperature is representative of the actual environment. This stabilization guarantees optimal accuracy for all measurements taken.
In summary, accuracy relies on proper pH calibration, automatic compensation for EC, and a stabilization time for temperature.
What is the EC, pH, and temperature precision for this BlueLab combo tester in compact microculture?
The BlueLab EC/pH + Temperature tester in compact microculture offers excellent precision for managing your crops:
- pH: precision of ±0.1 pH with a resolution of 0.1 pH, across a range of 0.0 to 14.0 pH. It easily calibrates in two points to ensure reliability.
- Electrical conductivity (EC): precision of ±0.1 mS/cm with a resolution of 0.1 mS/cm, across a range of 0 to 9.9 mS/cm, with integrated automatic temperature compensation.
- Temperature: precision of ±1 °C with a resolution of 1 °C, measuring from 0 to 50 °C, with no calibration needed.
These features ensure reliable measurements suitable for microculture and indoor gardening under LED, especially in hydroponics.
How long does the calibration of the BLUELAB-EC-PH-TEMP tester remain reliable in regular use?
The calibration of the BlueLab Combo EC/PH + Temperature tester is mandatory before the first pH measurement to ensure accuracy. However, the EC probe and temperature measurement remain reliable without frequent recalibration.
In regular use, it is recommended to regularly recalibrate the pH probe, ideally every 1 to 2 weeks, or with each intensive use, to maintain optimal accuracy. This recalibration is particularly important if you notice discrepancies in measurements, after cleaning or replacing the probe, or after changing batteries. The EC/Temperature probe, on the other hand, does not require frequent recalibration.
To ensure reliability, remember to clean the pH probe and use fresh buffer solutions for each calibration.
What are the accuracy and measurement range of the BlueLab EC PH Temperature Combo Tester for intensive hydroponic use?
The BlueLab EC/PH + Temperature Combo Tester is perfectly suited for intensive hydroponic use. It offers an accuracy of ±0.1 for pH, sufficient for rigorous control, and a resolution of 0.1 mS/cm for electrical conductivity (EC). Its measurement range covers from 0 to 14 for pH, and from 0.0 to 9.9 mS/cm for EC, which precisely meets the needs of hydroponic crops. Moreover, the temperature measurement includes automatic compensation, ensuring the reliability of all readings. A reliable, accurate, and easy-to-use tool to optimize the monitoring of your nutrient solutions.
What are the recommended calibration intervals for the BlueLab combo EC/PH + temperature tester to ensure accurate management during growth and flowering?
To ensure accurate management with the BlueLab Combo EC/PH + Temperature tester during growth and flowering, it is essential to calibrate the pH before its first use with a two-point calibration (pH 7.0, then pH 4.0 or 10.0). After that, regular recalibration of the pH is necessary, particularly:
- Before each critical session,
- If the results seem inconsistent,
- After changing batteries or probes,
- If the calibration indicators disappear.
The conductivity and temperature probe is factory calibrated and does not require recalibration, but regular cleaning is essential to ensure accuracy.
This diligence in maintenance and calibration ensures optimal control of nutrients and essential parameters throughout the cultivation.